1
0
mirror of https://git.tartarus.org/simon/putty.git synced 2025-01-25 09:12:24 +00:00
Commit Graph

1138 Commits

Author SHA1 Message Date
Simon Tatham
4fcb3bbe81 Move host CA config box out into its own source file.
In the course of polishing up this dialog box, I'm going to want it to
actually do cryptographic things (such as checking validity of a
public key blob and printing its fingerprint), which means it will
need to link against SSH utility functions.

So I've moved the dialog-box setup and handling code out of config.c
into a new file in the ssh subdirectory and in the ssh library, where
those facilities will be conveniently available.

This also means that dialog-box setup code _won't_ be linked into
PuTTYtel or pterm (on either platform), so I've added a stub source
file to provide its entry-point function in those tools. Also,
provided a const bool to indicate whether that dialog is available,
which we use to decide whether to recognise that command-line option.
2022-05-01 10:16:19 +01:00
Simon Tatham
694d5184b7 Permit button-only file selectors.
Instead of an edit box together with a Browse button that pops up a
sub-dialog, this is _just_ the browse button, only now it has a
user-defined title. I'm about to want to use this for loading CA
public keys from files.
2022-05-01 10:11:23 +01:00
Simon Tatham
259e877b92 New command-line option: 'putty --host-ca'.
This causes PuTTY to bring up just the host CA configuration dialog
box, and shut down once that box is dismissed.

I can imagine it potentially being useful to users, but in the first
instance, I expect it to be useful to _me_, because it will greatly
streamline testing changes to the UI of that dialog!
2022-05-01 10:11:03 +01:00
Simon Tatham
89883bf158 Restructure dlgcontrol as a struct with an anon union.
This gets rid of that awkward STANDARD_PREFIX system in which every
branch of the old 'union control' had to repeat all the generic
fields, and then call sites had to make an arbitrary decision about
which branch to access them through.

That was the best we could do before accepting C99 features in this
code base. But now we have anonymous unions, so we don't need to put
up with that nonsense any more!

'dlgcontrol' is now a struct rather than a union, and the generic
fields common to all control types are ordinary members of the struct,
so you don't have to refer to them as ctrl->generic.foo at all, just
ctrl->foo, which saves verbiage at the point of use.

The extra per-control fields are still held in structures named after
the control type, so you'll still say ctrl->listbox.height or
whatever. But now those structures are themselves members of an
anonymous union field following the generic fields, so those
sub-structures don't have to reiterate all the standard stuff too.

While I'm here, I've promoted 'context2' from an editbox-specific
field to a generic one (it just seems silly _not_ to allow any control
to have two context fields if it needs it). Also, I had to rename the
boolean field 'tabdelay' to avoid it clashing with the subsidiary
structure field 'tabdelay', now that the former isn't generic.tabdelay
any more.
2022-05-01 10:00:32 +01:00
Simon Tatham
77d15c46c3 New typedef 'dlgcontrol' wrapping 'union control'.
I'm about to change my mind about whether its top-level nature is
struct or union, and rather than change the key word 'union' to
'struct' at every point of use, it's nicer to just get rid of the
keyword completely. So it has a shiny new name.
2022-05-01 09:48:38 +01:00
Simon Tatham
e22df74545 Reorganise sk_namelookup (on both platforms).
I just tried to trace through the Windows version's control flow in
response to a confusing bug report, and found that the control flow
itself was so confusing I couldn't make sense of it. Why are we
choosing between getaddrinfo and gethostbyname via #ifndef NO_IPV6,
then re-converging control flow and diverging a second time to report
the error?

So I rewrote the whole thing to have completely separate sections of
code dealing with the three resolution strategies, each with its own
dedicated error reporting system. And then I checked the Unix version
and found it was about as confusing, so I rewrote that too in the same
style. Now the two are mostly the same, except for details: Unix has
an override at the top for a Unix socket pathname, Windows has to cope
with getaddrinfo maybe not being found at run time (so the other cases
aren't in the #else clause), and Windows uses the same error reporting
for both lookup functions whereas Unix has to use the appropriate
gai_strerror or hstrerror.
2022-04-29 12:01:23 +01:00
Simon Tatham
67204ffd0b Windows: stop trying to use gai_strerror.
To begin with, Windows's own API documentation doesn't recommend using
it (for thread-safety reasons), and promises that the error codes
returned from getaddrinfo are aliases for the normal Windows error
code enumeration. So it's safe, and quite likely preferable, to just
use ordinary win_strerror instead.

But more embarrassingly, my attempt to acquire and use gai_strerror
from one or other Winsock DLL didn't even *work*! Because of course
it's a function that handles strings, which means it comes in two
variants, gai_strerrorA and gai_strerrorW, so in order to look it up
using GetProcAddress, I should have specified which I wanted. And I
didn't, so the lookup always failed.

This should improve error reporting in cases of interesting kinds of
DNS failure.
2022-04-29 11:55:56 +01:00
Simon Tatham
03cfda89d1 Windows: make SockAddr's error field const char *.
We're assigning string literals into it all over the place, so it
should have been const char * all along. No thanks to any of the
compilers that didn't point that out!
2022-04-29 11:54:36 +01:00
Jacob Nevins
e6df50ea6b Restore 'Local' proxy type in config UI.
It was accidentally disabled in 2a26ebd0d5.
2022-04-29 11:39:04 +01:00
Simon Tatham
7b0292b2c3 Fix translation of legacy key format *again*.
As well as eliminating the null-pointer dereference, I also now
realise that the format-translation code depended on leaving the final
translated string in 'otherstr' in order to pass the host key check
afterwards (if they match).

I've also now realised that this only applies to *SSH-1* RSA keys, so
it's even more obsolete than I thought before. Perhaps I should just
remove this code instead of spending all this effort on fixing it. But
I've done the fix now, so I'll commit it, and then maybe we can remove
it afterwards (and have a working version of it available to resurrect
if ever needed!).
2022-04-28 12:50:00 +01:00
Simon Tatham
93fb65af61 Fix translation of legacy registry RSA key format.
A user points out that in commit 6143a50ed2, when I converted all
use of the registry to functions that return a newly allocated buffer
instead of allocating a buffer themselves beforehand, I overlooked
that one use of the old idiom was reusing the preallocated buffer as
work space.

I _hope_ nobody still needs this code - the 'old-style' host key cache
format it handles was replaced in 2000. If anyone has a PuTTY host key
cache entry that's survived 22 years without either having to be
reinitialised on a new system or changed when the machine's host key
was upgraded, they're doing better than I am!

But if it's still here, it should still work, obviously. Replaced the
reused buffer with a strbuf, which is more robust anyway.
2022-04-27 16:33:23 +01:00
Jacob Nevins
3bb7e6ba9e Fix duplicated shortcut on Windows SSH/Auth panel.
As of df3a21d97b, this panel has two "Browse..." buttons, and is the
first to do so. On Windows, the shortcut for this file chooser button
was hardcoded to 'w', causing an assertion failure whenever switching to
the Auth panel.

I've just removed the shortcut -- there are others near enough that it's
easy to reach the "Browse..." button with Tab.
2022-04-26 12:49:30 +01:00
Simon Tatham
21d4754b6a Initial support for host certificates.
Now we offer the OpenSSH certificate key types in our KEXINIT host key
algorithm list, so that if the server has a certificate, they can send
it to us.

There's a new storage.h abstraction for representing a list of trusted
host CAs, and which ones are trusted to certify hosts for what
domains. This is stored outside the normal saved session data, because
the whole point of host certificates is to avoid per-host faffing.

Configuring this set of trusted CAs is done via a new GUI dialog box,
separate from the main PuTTY config box (because it modifies a single
set of settings across all saved sessions), which you can launch by
clicking a button in the 'Host keys' pane. The GUI is pretty crude for
the moment, and very much at a 'just about usable' stage right now. It
will want some polishing.

If we have no CA configured that matches the hostname, we don't offer
to receive certified host keys in the first place. So for existing
users who haven't set any of this up yet, nothing will immediately
change.

Currently, if we do offer to receive certified host keys and the
server presents one signed by a CA we don't trust, PuTTY will bomb out
unconditionally with an error, instead of offering a confirmation box.
That's an unfinished part which I plan to fix before this goes into a
release.
2022-04-25 15:09:31 +01:00
Simon Tatham
7cb3142a57 PuTTYgen: options to add and remove certificates.
This allows you to actually use an OpenSSH user certificate for
authentication, by combining the PPK you already had with the
certificate from the CA to produce a new PPK whose public half
contains the certificate.

I don't intend that this should be the only way to do it. It's
cumbersome to have to use the key passphrase in order to re-encrypt
the modified PPK. But the flip side is that once you've done it you
have everything you need in one convenient file, and also, the
certificate itself is covered by the PPK's tamperproofing (in case you
can think of any attacks in which the admin of your file server swaps
out just the certificate for a different one on the same key). So this
is *a* useful way to do it, even if not the only useful way.

The new options to add and remove certificates are supported by both
Windows GUI PuTTYgen and cmdgen. cmdgen can also operate on pure
public keys, so you can say 'puttygen --remove-certificate
foo-cert.pub' and get back the underlying foo.pub; Windows PuTTYgen
doesn't support that mode, but only because it doesn't in general have
any support for the loaded key not being a full public+private pair.
2022-04-25 15:09:31 +01:00
Simon Tatham
2a26ebd0d5 Turn the proxy type radio buttons into a dropdown list.
This makes room to add more entries without the Proxy panel
overflowing. It also means we can put in a bit more explanation in
some of the more cryptic one-word names!
2022-04-25 14:10:16 +01:00
Simon Tatham
1bd2af1f87 Windows: refactor config-box creation code.
I'm about to want to create a second entirely different dialog box
whose contents are described using the same dialog.h API as the main
config box. So I'm starting by moving as much handler code as possible
out of GenericMainDlgProc and its callers, and into a set of reusable
subroutines.

In particular, this gets rid of the disgusting static variables that
stored all the config-box state. Now they're stored in a more sensible
struct, which lives in the new context-pointer field provided by the
reworked ShinyDialogBox.
2022-04-25 14:10:16 +01:00
Simon Tatham
cccdab9ba6 Windows: utility function to centre a window.
This was called from config box setup, and is obviously the kind of
thing that ought to be a reusable utility function.
2022-04-25 14:10:16 +01:00
Simon Tatham
69e8d471d1 Move our DialogBox wrapper into windows/utils.
It's self-contained enough not to really need to live in dialog.c as a
set of static functions. Also, moving it means we can isolate the
implementation details - which also makes it easy to change them.

One such change is that I've added the ability to bake a context
pointer into the dialog - unused so far, but it will be shortly.

(Also, while I'm here, renamed the functions so they sound more as if
they're adding features than working around bugs - not to mention not
imputing mental illness to the usual versions.)
2022-04-25 14:10:16 +01:00
Simon Tatham
6143a50ed2 windows/storage.c: factor out low-level Registry access.
All the fiddly business where you have to check that a thing exists,
make sure of its type, find its size, allocate some memory, and then
read it again properly (or, alternatively, loop round dealing with
ERROR_MORE_DATA) just doesn't belong at every call site. It's crying
out to be moved out into some separate utility functions that present
a more ergonomic API, so that the code that decides _which_ Registry
entries to read and what to do with them can concentrate on that.

So I've written a fresh set of registry API wrappers in windows/utils,
and simplified windows/storage.c as a result. The jump-list handling
code in particular is almost legible now!
2022-04-24 08:38:27 +01:00
Simon Tatham
a5c0205b87 Utility functions to get the algorithm from a public key.
Every time I've had to do this before, I've always done the three-line
dance of initialising a BinarySource and calling get_string on it.
It's long past time I wrapped that up into a convenient subroutine.
2022-04-24 08:38:27 +01:00
Simon Tatham
c0fba758e6 Standalone screenshot utility.
I used this for testing the new windows/utils/screenshot.c, and who
knows, it might come in useful again.
2022-04-02 17:26:24 +01:00
Simon Tatham
dec7d7fce7 Merge demo screenshot features from 'pre-0.77'. 2022-04-02 16:51:55 +01:00
Simon Tatham
bc7e06c494 Windows tools: assorted '-demo' options.
Using a new screenshot-taking module I just added in windows/utils,
these new options allow me to start up one of the tools with
demonstration window contents and automatically save a .BMP screenshot
to disk. This will allow me to keep essentially the same set of demo
images and update them easily to keep pace with the current appearance
of the real tools as PuTTY - and Windows itself - both evolve.
2022-04-02 17:23:34 +01:00
Simon Tatham
9294ee3496 Windows PuTTYgen: saw load_key_file in half.
Once we've actually loaded a key file, the job of updating the UI
fields is now done by a subroutine update_ui_after_load(), so that I
can call it from a different context in an upcoming commit.
2022-04-02 16:15:53 +01:00
Simon Tatham
35638a2631 Merge branch 'stuck' of /home/simon-win/src/putty into main 2022-03-29 18:09:43 +01:00
Simon Tatham
bdab00341b Cancel drag-select when the context menu pops up.
I got a pterm into a stuck state this morning by an accidental mouse
action. I'd intended to press Ctrl + right-click to pop up the context
menu, but I accidentally pressed down the left button first, starting
a selection drag, and then while the left button was still held down,
pressed down the right button as well, triggering the menu.

The effect was that the context menu appeared while term->selstate was
set to DRAGGING, in which state terminal output is suppressed, and
which is only unset by a mouse-button release event. But then that
release event went to the popup menu, and the terminal window never
got it. So the terminal stayed stuck forever - or rather, until I
guessed the cause and did another selection drag to reset it.

This happened to me on GTK, but once I knew how I'd done it, I found I
could reproduce the same misbehaviour on Windows by the same method.
Added a simplistic fix, on both platforms, that cancels a selection
drag if the popup menu is summoned part way through it.
2022-03-29 18:06:14 +01:00
Simon Tatham
f23a84cf7c windows/unicode.c: manually speak UTF-8.
This is another fallback needed on Win95, where the Win32 API
functions to convert between multibyte and wide strings exist, but
they haven't heard of the UTF-8 code page. PuTTY can't really do
without that these days.

(In particular, if a server sends a remote window-title escape
sequence while the terminal is in UTF-8 mode, then _something_ needs
to translate the UTF-8 data into Unicode for Windows to reconvert into
the character set used in window titles.)

This is a weird enough thing to be doing that I've put it under the
new #ifdef LEGACY_WINDOWS, so behaviour in the standard builds should
be unchanged.
2022-03-12 21:05:07 +00:00
Simon Tatham
3f76a86c13 Windows Pageant: deal with PeekMessageW failing on legacy Windows.
This makes Pageant run on Win95 again. Previously (after fixing the
startup-time failures due to missing security APIs) it would go into
an uninterruptible CPU-consuming spin in the message loop when every
attempt to retrieve its messages failed because PeekMessageW doesn't
work at all on the 95 series.
2022-03-12 21:05:07 +00:00
Simon Tatham
a2b376af96 Windows Pageant: turn 'has_security' into a global function.
Now it can be called from places other than Pageant's WinMain(). In
particular, the attempt to make a security descriptor in
lock_interprocess_mutex() is gated on it.

In return, however, I've tightened up the semantics. In normal PuTTY
builds that aren't trying to support pre-NT systems, the function
*unconditionally* returns true, on the grounds that we don't expect to
target any system that doesn't support the security APIs, and if
someone manages to contrive one anyway - or, more likely, if we some
day introduce a bug in our loading of the security API functions -
then this safety catch should make Pageant less likely to accidentally
fall back to 'never mind, just run in insecure mode'.
2022-03-12 21:05:07 +00:00
Simon Tatham
f500d24a95 Windows: runtime switch between Unicode and ANSI windows.
Turns out that PuTTY hasn't run successfully on legacy Windows since
0.66, in spite of an ongoing intention to keep it working. Among the
reasons for this is that CreateWindowExW simply fails with
ERROR_CALL_NOT_IMPLEMENTED: apparently Win95 and its ilk just didn't
have fully-Unicode windows as an option.

Fixed by resurrecting the previous code from the git history (in
particular, code removed by commit 67e5ceb9a8 was useful), and
including it as a runtime alternative.

One subtlety was that I found I had to name the A and W window classes
differently (by appending ".ansi" to the A one): apparently they
occupy the same namespace even though the names are in different
character sets, so if you somehow manage to register both classes,
they'll collide with each other without that tweak.
2022-03-12 21:05:07 +00:00
Simon Tatham
accf9adac2 Merge legacy-Windows fixes (mostly) from 'pre-0.77'. 2022-03-12 20:22:48 +00:00
Simon Tatham
01c007121a Remove hard dependencies on multi-monitor functions.
These are more functions that don't exist on all our supported legacy
versions of Windows, so we need to follow the same policy as
everywhere else, by trying to acquire them at run time and having a
fallback if they aren't available.
2022-03-12 18:51:21 +00:00
Simon Tatham
83ff08f9db Remove hard dependency on GetFileAttributesEx.
This fixes a load-time failure on versions of Windows too old to have
that function in kernel32.dll.

We use it to determine whether a file was safe to overwrite in the
context of PuTTY session logging: if it's safe, we skip the 'do you
want to overwrite or append?' dialog box.

On earlier Windows you can use FindFirstFile to get a similar effect,
so that's what we fall back to. It's not quite the same, though - if
you pass a wildcard then it will succeed when you'd rather it had
failed. But it's good enough to at least work in normal cases.
2022-03-12 18:51:21 +00:00
Simon Tatham
26dcfcbd44 Make init_winver() idempotent.
This way, anyone who needs to use the version data can quickly call
init_winver to make sure it's been set up, and not waste too much faff
redoing the actual work.
2022-03-12 18:51:21 +00:00
Simon Tatham
5de1df1b94 Windows: avoid idempotent window title changes.
By testing on a platform slow enough to show the flicker, I happened
to notice that if your shell prompt resets the window title every time
it's displayed, this was actually resulting in a call to SetWindowText
every time, which caused the GUI to actually do work.

There's certainly no need for that! We can at least avoid bothering if
the new title is identical to the old one.
2022-03-12 18:51:21 +00:00
Simon Tatham
901667280a Windows: initialise window_name and icon_name.
It turns out that they're still NULL at the first moment that a
SetWindowText call tries to read one of them, because they weren't
initialised at startup! Apparently SetWindowText notices that it's
been passed a null pointer, and does nothing in preference to failing,
but it's still not what I _meant_ to do.
2022-03-12 18:51:21 +00:00
Simon Tatham
fe00a2928c Windows: diagnose failure to create the terminal window.
It only fails in very unusual circumstances, but that's all the more
reason to give a useful report when it does!
2022-03-12 18:51:21 +00:00
Simon Tatham
269ea8aaf5 Move predeclaration of struct unicode_data into defs.h.
It's just the sort of thing that ought to be in there, once, so it
doesn't have to be declared in n places.
2022-03-12 18:51:21 +00:00
Simon Tatham
5243a2395a Merge pterm process-exit fix from 'pre-0.77'. 2022-03-08 18:06:13 +00:00
Simon Tatham
ee987ce4cd pterm.exe: fix handling of Windows exception codes.
Unlike on Unix, a Windows process's exit status is a DWORD, i.e. a
32-bit unsigned integer. And exit statuses seen in practice can range
up into the high half of that space. For example, if a process dies of
an 'illegal instruction' exception, then the exit status retrieved by
GetExitCodeProcess will be 0xC000001D == STATUS_ILLEGAL_INSTRUCTION.

If this happens to the process running inside pterm.exe, then
conpty->exitstatus will be set to a value greater than INT_MAX, which
will cause conpty_exitcode to return -1. Unfortunately, a -1 return
from conpty_exitstatus is treated by front ends as saying that the
backend process hasn't exited yet, and is still running. So pterm will
sit around after its subprocess has already terminated, contrary to
your 'close on exit' setting.

Moreover, when cmd.exe exits, it apparently passes on to its parent
process the exit status of the last subcommand it ran. So if you run a
Windows pterm containing an ordinary interactive console session, and
the last subprogram you happen to run inside that session dies of a
fatal signal, then the same thing will happen after you type 'exit' at
the command prompt.

This has been happening to me intermittently ever since I created
pterm.exe in the first place, and I guessed completely wrong about the
cause (I feared some kind of subtle race condition in pterm's use of
the process API). I've only just managed to reproduce it reliably
enough to debug, and I'm relieved to find it's much simpler than that!

The immediate fix, in any case, is to ensure we don't return -1 from
conpty_exitcode unless the process really is still running. And don't
return INT_MAX either, because that indicates 'unclean exit' in a way
that triggers 'close window only on clean exit' (and even Unix pterm
doesn't consider the primary subprocess dying of a signal to count as
unclean). So we clip all out-of-range Windows exception codes to
INT_MAX-1.

In the longer term I think it would be nice to turn exit codes into a
full 32-bit space, and move the special values completely out of it.
That would permit actually keeping the exact exception code and
passing it on to a caller who needed it. For example, if we were to
write a Windows psusan (which I could imagine being occasionally
useful), this way it would be able to return the unmodified full
Windows exit code via the "exit-status" chanreq. But I don't think we
currently have any clients needing that much detail, so that's a more
intrusive cleanup for a later date.
2022-03-08 18:05:48 +00:00
Simon Tatham
6f8db22972 Windows Pageant: option to open an AF_UNIX socket.
There's now a command-line option to make Pageant open an AF_UNIX
socket at a pathname of your choice. This allows it to act as an SSH
agent for any client program willing to use a WinSock AF_UNIX socket.

In particular, this allows WSL 1 processes to talk directly to Windows
Pageant without needing any intermediate process, because the AF_UNIX
sockets in the WSL 1 world interoperate with WinSock's ones.

(However, not WSL 2, which isn't very surprising.)
2022-02-05 12:58:41 +00:00
Simon Tatham
82971a3ebb Handle WM_NETEVENT in Windows Pageant.
Apparently when I made Windows Pageant use the winselgui system, I
added the call that gets WSAAsyncSelect response messages sent to
Pageant's window, but I didn't add the switch case in the window
procedure that actually handles those responses. I suppose I didn't
notice at the time because no actual functionality used it - Pageant
has never yet dealt with any real (i.e. Winsock) sockets, only with
HANDLE-based named pipes, which are called 'sockets' in PuTTY's
abstraction, but not by Windows.
2022-02-04 19:32:47 +00:00
Simon Tatham
018236da29 Support AF_UNIX listening sockets on Windows.
Not all Windows toolchains have this yet, so we have to put the
whole lot under #ifdef.
2022-02-04 19:32:47 +00:00
Simon Tatham
3d15342fe8 windows/network.c: refactor addr family in sk_newlistener.
Most of the previous large sk_newlistener function is now an inner
function whose address-family parameter is a platform AF_FOO constant
rather than one of our own ADDRTYPE_FOO. sk_newlistener itself is a
trivial wrapper on that, which just does the initial translation from
the input ADDRTYPE_FOO into an AF_FOO.

This will make it possible to drop in alternative wrapper functions
which won't have to make up a pointless ADDRTYPE.
2022-02-04 19:28:56 +00:00
Simon Tatham
04cc999b50 windows/network.c: refactor SOCKADDR_FAMILY.
This macro is now an inline function, and as in the previous commit,
each possible value for the main discriminator is now a case in a
switch statement instead of tested in an interlocking set of ?:.
2022-02-04 19:28:02 +00:00
Simon Tatham
5b5904b7cc windows/network.c: refactor switch in sk_newlistener.
The code that diverges based on the address family is now in the form
of a switch statement, rather than an unwieldy series of chained ifs.
And the final call to bind() has all its arguments worked out in the
previous switch, rather than computing them at the last minute with an
equally unwieldy set of ?: operators that repeat the previous test.

This will make it easier to add more cases, and also, to keep each
case under its own ifdef without losing too much legibility.
2022-02-04 19:26:25 +00:00
Simon Tatham
f08879a556 windows/network.c: create a 'superfamily' SockAddr field.
This replaces two previous boolean fields 'resolved' and 'namedpipe',
converting them into a single three-valued enum which avoids being
able to represent the meaningless fourth possibility at all. Also, it
provides an open-ended place to add further possibilities.

The new field is very similar to the one in unix/network.c, except
that the UNIX entry for AF_UNIX sockets is missing, and in its place
is the NAMEDPIPE entry for storing the pathnames of Windows named
pipes.
2022-02-04 19:25:35 +00:00
Simon Tatham
dd3d0e931f windows/network.c: reformat some mis-indented code.
Not quite sure how this all ended up a whole indent level off where it
should have been, but before I start modifying it, let's fix that.
2022-02-04 19:25:35 +00:00
Simon Tatham
b7ed5056e5 net_service_lookup: add missing 'const'.
Spotted in passing while doing the filename-correction trawl.
2022-01-22 15:51:33 +00:00
Simon Tatham
5935c68288 Update source file names in comments and docs.
Correcting a source file name in the docs just now reminded me that
I've seen a lot of outdated source file names elsewhere in the code,
due to all the reorganisation since we moved to cmake. Here's a giant
pass of trying to make them all accurate again.
2022-01-22 15:51:31 +00:00